Wayne SYLT30 Instrukcje Operacyjne

Przeglądaj online lub pobierz Instrukcje Operacyjne dla Pompy wodne Wayne SYLT30. Wayne SYLT30 Operating instructions Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
1/3 HP Sink Pump
System
Description
This system pumps water up to an
existing water drain and is designed for
residential use in laundry trays, washing
machines, wet bar sinks, sinks and tubs,
dehumidifiers, and air conditioners.
The submersible sump pump included
in this system is equipped with an 8-ft
long, 3-prong grounding type power
cord. Motor is oil filled and sealed for
cooler running and designed to operate
under water. A float switch is provided
for automatic pump operation. This
pump is not suitable for aquatic life.
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged during
shipment. If the pump or components
are damaged, call our customer service
department at 1-800-237-0987.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
Danger indicates an
imminently
hazardous situation which, if not avoided,
WILL result in death or serious injury.
Warning indicates a
potentially
hazardous situation which, if not avoided,
COULD result in death or serious injury.
Caution indicates a
potentially
hazardous situation which, if not avoided,
MAY result in minor or moderate injury.
Notice indicates
important
information, that if not followed, MAY
cause damage to equipment.
local electrician for installation and
availability.
7. This pump is designed to transfer
water in cycles. Using this pump in
a continuous duty application by
ma nip u lat ing the switch to stay on,
will effect the per for mance and the
life of the product.
8. Protect electrical cord from sharp
objects, hot sur fac es, oil, and
chemicals. Avoid kinking the cord.
Re place or repair damaged or worn
cords im me di ate ly. Use wire of
adequate size to minimize voltage
drop at the motor.
9. Do not handle a pump or pump motor
with wet hands or when standing on a
wet or damp surface, or in water.
Do NOT
walk on
wet area until all power has
been turned off. If the shut-off
box is in basement, call the
electric company to shut-off service to the
house, or call the local fi re department for
instructions. Remove pump and repair or
replace. Failure to follow this warning can
result in fatal electrical shock.
Assembly
Assembly Instructions:
1. Remove packaging, including the
foam inside the tank.
2. Apply gasket to top of tank, just
outside the opening. (See Figure 1)
General Safety
Information
CALIFORNIA PROPOSITION 65
This product or
its power cord may
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
GENERAL SAFETY INFORMATION
1. Know the pump application,
limitations, and po ten tial hazards.
Do NOT
use to
pump fl ammable or explosive
uids such as gasoline, fuel oil,
kerosene, etc. Do NOT use in
ammable and/or explosive atmospheres.
Use pump only with liquids compatible
with pump component materials. Failure
to follow this warning can result in
personal injury and/or property damage.
Disconnect
power
before servicing. If the power
dis con nect is out of sight, lock
in the open po si tion and tag
it to prevent unexpected application of
power. Failure to do so could result in fatal
electrical shock!
2. Drain all liquids from the system
before servicing.
3. Periodically inspect the pump
and system com po nents. Perform
routine maintenance as required
(See maintenance section).
4. When wiring an elec tri cal ly driven
pump such as this, fol low all
electrical and safety codes, as well as
the most recent National Electrical
Code (NEC) and the Oc cu pa tion al
Safety and Health Act (OSHA).
5. All wiring should be performed by a
qualified elec tri cian.
6. It is strongly recommended that this
unit is plugged into a Ground Fault
Circuit Interrupter (GFCI). Con sult a
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain
the product described. Protect yourself and others by observing all safety information. Failure to comply with
instructions could result in personal injury and/or property damage! Retain instructions for future reference.
For parts, product & service information
visit www.waynepumps.com
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
332800-001 3/11
Operating Instructions & Parts Manual SYLT30
© 2011, WAYNE Water Systems/Scott Fetzer.
Figure 1: Adding Lid Gasket to Tank
Przeglądanie stron 0
1 2 3 4 5 6 ... 19 20

Podsumowanie treści

Strona 1 - 1/3 HP Sink Pump

1/3 HP Sink Pump System Description This system pumps water up to an existing water drain and is designed for residential use in laundry trays, washin

Strona 2 - Assembly (continued)

Fr 10Instructions d'Utilisation et Pièces de RecahngeProblème Cause(s) Possible(s) Mesure(s) corrective(s)La pompe ne démarre pas ou ne fonctionn

Strona 3 - Maintenance

SYLT30Numéro de référence Description Numéro de pièce Quantité1 Impulseur 60138-001 12 Volute 28539-001 13 Base 28540-001 14 Trousse de clapet de non-

Strona 4 - Troubleshooting Chart

Fr 12 Garantie LimitéePour un (1) an à compter de la date d’achat, WAYNE Water Systems (« WAYNE ») réparera ou remplacera, à son choix, pour l’acheteu

Strona 5 - Call 1-800-237-0987

Sistema de bomba para pileta de 1/3 HP Descripción Este sistema bombea agua hasta un drenaje de agua existente y está diseñado para uso residencial en

Strona 6 - Limited Warranty

4. Pase el cable de corriente y el cable del interruptor a través de los orificios del sellado del cable de corriente.5. Introduzca los sellos en los

Strona 7 - Système / pompe

Sp 15Funcionamiento Siempre desconecte la fuente de energía antes de intentar instalar, efectuar un servicio, reubicar o realizar el mantenimiento

Strona 8 - Assemblage (suite)

Sp 16Manual de Instrucciones y RepuestosProblema Causa(s) posible(s) Acciones a tomarLa bomba no enciende o no funciona 1. Fusible quemado, disyuntor

Strona 9 - Fonctionnement

SYLT30Número de Ref. Descripción Numero de pieza Ctd.1 Impulsor 60138-001 12 Voluta 28539-001 13 Base 28540-001 14 Conjunto de válvula de retención 60

Strona 10 - Dépannage

Sp 18Manual de Instrucciones y RepuestosNotas

Strona 12 - Garantie Limitée

3. Place pump assembly inside tank, keeping fl oat away from the walls of the tank.4. Run power cord and switch cord through holes in the power cord

Strona 13 - Sistema de bomba

Sp 20Manual de Instrucciones y Repuestos Garantía LimitadaDurante uno (1) año, WAYNE Water Systems (“WAYNE”) reparará o reemplazará, según lo decida,

Strona 14 - Ensamblaje (continuación)

3www.waynepumps.comOperation Always disconnect the power source before attempting to install, service, relocate or maintain the pump. NEVER touch the

Strona 15 - Maintenimiento

4www.waynepumps.comOperating Instructions and Parts ManualProblem Possible Cause(s) Corrective Action(s)Pump will not start or run 1. Blown fuse, tri

Strona 16

For Replacement Parts or Technical Assistance,Call 1-800-237-0987Please provide following information: Address any correspondence to:- Model number

Strona 17

6www.waynepumps.comLimited Warranty For one (1) year from the date of purchase, WAYNE Water Systems ("WAYNE") will repair or replace, at its

Strona 18

Système / pompe d’évier de 1/3 CHDescription Ce système pompe l’eau jusqu’à un drain de vidange en place et il est conçu pour une utilisation résident

Strona 19

3. Placer l’assemblage de pompe à l’intérieur du réservoir en gardant le flotteur loin des parois du réservoir.4. Acheminer le cordon d’alimentation e

Strona 20 - Garantía Limitada

Fr 9Fonctionnement Toujours couper lasource de courant avant d’essayer d’installer, de réparer, de déplacer ou de faire l’entretien de la pompe. NE

Komentarze do niniejszej Instrukcji

Brak uwag