ConstructionHeaterC USVG175Installation and Maintenance ManualPlease retain this manual for future reference.342 N. Co. Rd. 400 East Valpara
101. Turn the heater to position #1 and nothing happens.2. The heater runs for a littlewhile, but shuts down. Itwon’t come onagain until I reset the
113. The heater has a loud rumbling sound.4. Burner motor comes on, but the heater won’t ignite.• Air damper setting• Dirt on burner blower wheel• Flu
124. Continued5. The heater blows black smoke out of the vent stack.• Gas valve• Air damper setting• Dirt on burner blower wheel• Improper flue pipe s
136. The burner seems to cycle on and off more than it should.7. The burner starts, but the main fan never comes on.• Gas manifold pressure• Dirt on m
148. The burner continues to run, but the fan cycles on and off.• Gas manifold pressure• Fuel supply pressure and volume• Fan sensor• Heater Control U
15Also see Control Box Parts page 17.Heat Wagon VG175 Parts ListITEM PART# DESCRIPTION1 HWP 2709001 HEATER FRAME2 HWP 2709002 COVER PLATE3 HWP 2709003
16WAYNE BURNER PARTS BREAKDOWNITEM PART# DESCRIPTION1 62700-002 Bracket, Control Mounting2 16635-002 Washer, Flat #83 63244-002 Screw, Fillester 10-24
17120 Volt 1 PHITEM PART# DESCRIPTIONE1 HWP 41000 MAIN CONTROL BOX(Fibox 175x125x100 MM)E2 HWP 40850 THERMOSTAT BOX (Fibox 125x125x75 MM)E3 HWP 40900
18120 Volt 1 PH
EXHAUST FLUE PIPE GUIDELINES67810TOTAL VENT HEIGHT,H,H,FEETLATERAL LENGTH, L, FEET60205 285 370 5702 157 217 285 4556 149 205 273 43512 137 190 255 40
IMPORTANT INFORMATION! READ FIRSTThe heater is designed for use as a construction heater under ANSI Z83.7a-2000. The primarypurpose of construction he
We Stock A Complete Line Of Parts & AccessoriesDUCTINGTHERMOSTATLOCK BOXESHOSESREGULATORS342 N. Co. Rd. 400 East Valparaiso, IN 46383219-464-8818
Table of Contents:PageSafety & Caution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Specifications .
SPECIFICATIONSModel No. VG175Fuels: Vapor Propane or Natural Gas Capacity: 175,000 BTU/HR*Blower: 1,400 CFM 1/2” SPElectrical Rating: 120 Volts, 10 Am
OPERATING INSTRUCTIONSINSTALLATION• When transporting, use both lifting eyes located on sides of heater. • Place the unit on a level and non-combustib
FUEL SUPPLY (CONTINUED)• Ensure that for the surrounding temperature, size and capacity of the propane supply cylinder is adequate to provide the rate
START UP (CONTINUED)4. Turn the control switch on the control box to position “1” (HEATING).5. When the ambient temperature level is low, the burner
MAINTENANCEPrior to starting any maintenance work be sure to disconnect unit from power supply until unit cools down fully and fan shuts off! (Shut D
SERVICE• The complete unit, including heat exchanger, combustion chamber and burner should be cleaned from dust and dirt after every heating period, a